- HOME
- PRODUCTS
- MV & HV Series
- MV & HV Distributed Energy Storage Products
MV & HV Distributed Energy Storage Products
Advanced Safety Design
- 3+2 Safety System: Three-tier fire protection design + dual safety assurance
- Al-Based Early Warning: Utilizing automotive-grade battery cells for Al-enabled battery fault warning
Streamlined and Flexible
- Efficient Layout: Vertical alignment of AC and DC components, reducing the footprint of PCS and water cooling units, decreasing product volume by 25%.
- Dynamic Capacity Expansion: Supporting side-by-side and back-to-back mounting to maximize space utilization, ensuring flexibility and scalability without limitations on site layout.
Lower LCOS
- Ultra-long Life: Enhancing battery pack consistency to extend system life by 20%.
- Efficient Heat Dissipation: Utilizing liquid-cooled pack, maintaining a cell temperature difference less than 2.8°C, and reducing auxiliary energy consumption by 30%.
- Separate Management of Each Cluster: The inter -cluster voltage balancing control eliminates the barrel effect, yielding an 8% increase in capacity over the battery lifecycle.
Convenient and Reliable
- Easy Grid Connection: Comprehensive performance and functional testing conducted prior to shipment, eliminating the need for on-site commissioning.
- Minimal Dismantling Requirement: Assigning one PCS per cluster achieves 90% reduction in fault losses.
- Robustness in Challenging Environments: Ability to withstand diverse outdoor conditions, including high temperatures, extreme cold, high humidity, and high altitudes.
Intelligent Management
- Remote Management: Online intelligent monitoring for decreased manual inspection frequency.
- Dynamic Adjustment: High SOC accuracy enables dynamically adapting energy management strategies based on load requirements.
MV & HV Distributed Energy Storage Products
Advanced Safety Design
- 3+2 Safety System: Three-tier fire protection design + dual safety assurance
- Al-Based Early Warning: Utilizing automotive-grade battery cells for Al-enabled battery fault warning
Streamlined and Flexible
- Efficient Layout: Vertical alignment of AC and DC components, reducing the footprint of PCS and water cooling units, decreasing product volume by 25%.
- Dynamic Capacity Expansion: Supporting side-by-side and back-to-back mounting to maximize space utilization, ensuring flexibility and scalability without limitations on site layout.
Lower LCOS
- Ultra-long Life: Enhancing battery pack consistency to extend system life by 20%.
- Efficient Heat Dissipation: Utilizing liquid-cooled pack, maintaining a cell temperature difference less than 2.8°C, and reducing auxiliary energy consumption by 30%.
- Separate Management of Each Cluster: The inter -cluster voltage balancing control eliminates the barrel effect, yielding an 8% increase in capacity over the battery lifecycle.
Convenient and Reliable
- Easy Grid Connection: Comprehensive performance and functional testing conducted prior to shipment, eliminating the need for on-site commissioning.
- Minimal Dismantling Requirement: Assigning one PCS per cluster achieves 90% reduction in fault losses.
- Robustness in Challenging Environments: Ability to withstand diverse outdoor conditions, including high temperatures, extreme cold, high humidity, and high altitudes.
Intelligent Management
- Remote Management: Online intelligent monitoring for decreased manual inspection frequency.
- Dynamic Adjustment: High SOC accuracy enables dynamically adapting energy management strategies based on load requirements.
Product Specifications
R372L1
R372L2
R418L1
R407L1
Rated Power
186kW
186kW
209kW
204kW
Rated Energy
372.74kWh
372.74kWh
418 kWh
407.35 kWh
Single Cell
3.2V 280Ah
3.2V 280Ah
3.2V 314Ah
3.2V 306Ah
Battery Pack
1P52S*8
1P52S*8
1P52S*8
1P52S*8
DC Voltage
1164.8~1497.6V
1164.8~1497.6V
1164.8~1497.6V
1164.8~1497.6V
Rated AC Voltage
690V
690V
690V
690V
Rated Output
156A
156A
175A
171A
Protection Grade
IP54
IP54
IP54
IP54
Thermal Management Technology
Liquid cooling
Liquid cooling
Liquid cooling
Liquid cooling
Dimensions (W*D*H)
1402*1338*2320mm
≈1402*1338*2320mm
≈1402*1338*2320mm
≈1402*1338*2320mm
Weight
≈3300kg
≈3400kg
≈3500kg
≈3500kg
Design Life
15 years
15 years
15 years
15 years
Max. Allowable Altitude
4,000 meters (derating above 2,000 meters)
4,000 meters (derating above 2,000 meters)
4,000 meters (derating above 2,000 meters)
4,000 meters (derating above 2,000 meters)
Internal Isolation Method
No Transformer
No Transformer
No Transformer
No Transformer
Temperature & Humidity Requirements
-30℃~50℃
-30℃~50℃
-30℃~50℃
-30℃~50℃
System Efficiency
88.5%
88.5%
88%
89%
Max. Efficiency
89.5%
89.5%
89%
90%
Structure
Left-right
Left-right
Left-right
Left-right
R372L1
R372L2
R418L1
R407L1
Rated Power
186kW
209kW
204kW
Rated Energy
372.74kWh
418 kWh
407.35kWh
Single Cell
3.2V 280Ah
3.2V 314Ah
3.2V 306Ah
Battery Pack
1P52S*8
DC Voltage
1164.8~1497.6V
Rated AC Voltage
690V
Rated Output
156A
175A
171A
Protection Grade
IP54
Thermal Management Technology
Liquid cooling
Dimensions (W*D*H)
≈1402×1338×2320mm
Weight
≈3300kg
≈3400kg
≈3500kg
Design Life
15 years
Max. Allowable Altitude
4,000 meters (derating above 2,000 meters)
Internal Isolation Method
No Transformer
Temperature & Humidity Requirements
-30℃~50℃
System Efficiency
88.5%
88%
89%
Max. Efficiency
89.5%
89%
90%
Structure
Left-right
Energy Storage Solutions
System Architecture
MORE PRODUCTS